| Home | E-Submission | Sitemap | Contact Us |  
top_img
J Korean Soc Emerg Med > Volume 32(2); 2021 > Article
Journal of The Korean Society of Emergency Medicine 2021;32(2): 162-169.
요골동맥 천자 보조 도구의 초기 경험
이규하 , 김양원 , 강지훈 , 박철호 , 지재구 , 이시원 , 윤유상
인제대학교 의과대학 응급의학교실
Early experiences of the device guided radial artery puncture
Gyu Ha Lee , Yang Weon Kim , Ji Hun Kang , Chul Ho Park , Jae Gu Ji , Si Won Lee , Yoo Sang Yoon
Department of Emergency Medicine, Inje University College of Medicine, Busan, Korea
Correspondence  Yoo Sang Yoon ,Tel: 051-890-6120, Fax: 051-891-1465, Email: 101mars@hanmail.net,
Received: June 29, 2020; Revised: August 13, 2020   Accepted: August 21, 2020.  Published online: April 30, 2021.
ABSTRACT
Objective:
Although several studies have been conducted on the use of ultrasound to assist in arterial punctures, its utility is controversial and it is also inconvenient to use the equipment in the emergency room. Therefore, we developed a radial artery puncture assistive device for use in the emergency room and evaluated its utility.
Method:
The operator attempted the procedure on a mannequin, both with and without the device. We recorded the first-attempt success rate, the number of punctures, the time to success, and the failure rate. We conducted a survey to assess pre-experiment expectation and post-experiment satisfaction.
Results:
The first-attempt success rate was 78% with no device and 66% with the device (P=0.105). The failure rate was 5% both when the device was not worn and worn (P>0.99). The number of attempts was 2.18 with no device and 2.10 with the device (P=0.765). The time to success was 40.81 seconds without the device and 54.08 seconds with the device (P=0.307). The responses to the pre-experiment survey were 5% for ‘Not wearing the device seems to be more helpful’, 75% for ‘Wearing the device seems to be more helpful’, and 20% for ‘There seems to be no difference’. In the postexperiment survey, the responses were 30% for ‘Not wearing the device was more helpful’, 55% for ‘Wearing the device was more helpful’, and 15% for ‘There was no difference’.
Conclusion:
There were no significant results from the experiments. But respondents felt that wearing the device was better in both the pre-experiment and post-experiment survey.
Key words: Radial artery; Punctures; Equipment and supplies
TOOLS
PDF Links  PDF Links
Full text via DOI  Full text via DOI
Download Citation  Download Citation
Share:      
METRICS
767
View
53
Download
Related article
Editorial Office
The Korean Society of Emergency Medicine
TEL: +82-62-226-1780   FAX: +82-62-224-3501   E-mail: 0012194@csuh.co.kr
About |  Browse Articles |  Current Issue |  For Authors and Reviewers
Copyright © The Korean Society of Emergency Medicine.                 Developed in M2PI