| Home | E-Submission | Sitemap | Contact Us |  
top_img
J Korean Soc Emerg Med > Volume 29(1); 2018 > Article
Journal of The Korean Society of Emergency Medicine 2018;29(1): 44-50.
Comparison of Intubation Efficiency by Suction Device in a Hemorrhagic Airway Manikin Model: Yankauer Suction Tip vs. Polyvinyl Chloride Catheter Suction Tip
Hyo Bin Lee1, Yoon Sun Jung2, Gil Joon Suh2,3, Woon Yong Kwon2,3
1Department of Emergency Medicine, National Medical Center, Seoul, Korea
2Department of Emergency Medicine, Seoul National University Hospital, Seoul, Korea
3Department of Emergency Medicine, Seoul National University College of Medicine, Seoul, Korea
Correspondence  Yoon Sun Jung ,Tel: 02-2072-4850, Fax: 02-741-7855, Email: loctos00@hanmail.net,
Received: September 13, 2017; Revised: September 14, 2017   Accepted: November 6, 2017.  Published online: February 28, 2018.
ABSTRACT
Purpose:
Tracheal intubation in a hemorrhagic airway is a difficult procedure because the visibility can be obscured by blood or vomitus. Several devices and methods have been developed to overcome such obstacles, but they are not available at all practical sites. Therefore, this study was conducted to assess the time and success rate of tracheal intubation according to the type of suction tip used in a hemorrhagic airway manikin model.
Method:
This study was a randomized crossover manikin simulation study. We recruited 18 emergency physicians to perform intubation with suction using a Yankauer suction tip and a polyvinyl chloride (PVC) catheter suction tip in a hemorrhagic airway manikin model. We then measured the time and success rate of intubation for each suction tip.
Results
The mean intubation time using the Yankauer suction tip was 42.3 seconds, and the mean intubation time using the PVC catheter suction tip was 91.1 seconds (p<0.001). Two cases of esophageal intubation occurred when the PVC catheter suction tip was used (success rate, 88.9%). In contrast, there was no esophageal intubation when the Yankauer suction tip was used (success rate, 100%) (p=0.217).
Conclusion:
Intubation of a hemorrhagic airway manikin model can be performed in a shorter time when a Yankauer suction tip is used than when a PVC catheter suction tip is used.
Key words: Airway, Hemorrhage, Suction, Manikin
TOOLS
PDF Links  PDF Links
Full text via DOI  Full text via DOI
Download Citation  Download Citation
Share:      
METRICS
1,732
View
70
Download
Related article
Editorial Office
The Korean Society of Emergency Medicine
TEL: +82-62-226-1780   FAX: +82-62-224-3501   E-mail: 0012194@csuh.co.kr
About |  Browse Articles |  Current Issue |  For Authors and Reviewers
Copyright © The Korean Society of Emergency Medicine.                 Developed in M2PI