| Home | E-Submission | Sitemap | Contact Us |  
top_img
J Korean Soc Emerg Med > Volume 17(3); 2006 > Article
Journal of The Korean Society of Emergency Medicine 2006;17(3): 225-230.
A Comparison of Bioimpedance and Echocardiography in Measuring Cardiac Output in Healthy Male Volunteers
Gyu Chong Cho, Won Kim, Yoo Dong Sohn, Hui Dong Kang, Bum Jin Oh, Kyoung Soo Lim
Department of Emergency Medicine, College of Medicine, Ulsan University, Seoul, Korea. wkim@amc.seoul.kr
ABSTRACT
PURPOSE:
To manage a critically ill patient effectively, an emergency physician must make an accurate assessment of the patient's hemodynamic status. Although the hemodynamic status can be accurately measured through the use of a pulmonary artery catheter, this device has significant limitations in the emergency department. Instead, the most commonly used method of measuring cardiac output (CO) in the emergency department is transthoracic echocardiography (TTE). However, TTE has been reported to underestimate the CO. Impedance cardiography (ICG) is an established and accurate technique for noninvasive determination of hemodynamic parameters. Thus, this study aimed to assess the agreement between CO measurements made by using TTE and ICG.
METHODS:
In 20 healthy volunteers, the hemodynamic parameters (stroke volume and CO) obtained by TTE were compared with the parameters derived from simultaneous measurements by ICG.
RESULTS:
The mean stroke volumes and COs were 63.9+/-11.6 ml and 4.1+/-0.7 L/min, respectively, by TTE, and 77.2+/-10.2 ml and 5.0+/-0.6 L/min by ICG. The correlation coefficients for stroke volume and CO between TTE and ICG were 0.77 and 0.64. The mean difference in stroke volume between TTE and ICG was -13.3+/-6.4 ml (-19.5+/-10.5 %), and the mean difference in CO was -0.88+/-0.48 L/min (-20.1+/-11.6 %).
CONCLUSION:
In healthy volunteers, the comparison between TTE and ICG showed a good correlation for stroke volume and CO. However, the mean differences in stroke volume and CO between TTE and ICG were -19.5+/-10.5 % and -20.1+/-11.6 %, respectively.
Key words: Echocardiography, Impedance cardiography, Cardiac output
TOOLS
PDF Links  PDF Links
Full text via DOI  Full text via DOI
Download Citation  Download Citation
Share:      
METRICS
1,276
View
9
Download
Related article
Role of Two-Dimensional Echocardiography in Diagnosis of Cardiovascular Injuries in Blunt Chest Trauma  1997 September;8(3)
Editorial Office
The Korean Society of Emergency Medicine
TEL: +82-62-226-1780   FAX: +82-62-224-3501   E-mail: 0012194@csuh.co.kr
About |  Browse Articles |  Current Issue |  For Authors and Reviewers
Copyright © The Korean Society of Emergency Medicine.                 Developed in M2PI